Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Voltage Ui: 230V AC/500V AC;
Short-Circuit Current Inc=IΔc: 10ka;
Rated Current: 25A /40A /63A/80A/100A;
Rated Residual Operating Current: 30mA/100mA/300mA;
Poles: 2p/4p;
Rated Frequency: 50/60Hz;
Mode: Electromagnetic / Electronic;
Uimp: 4kv;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 1p+N/2p/3p+N/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: 240V /415V AC;
Inc: 6ka;
Rated Residual Operating Current(I: 30mA/100mA/300mA;
Rated Current: 6-63A;
Tripping Curve: B/C/D;
Mode: Electronic /Electromagnetic;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Air Circuit Breaker;
Orign of Place: Zhejiang, China;
Related Voltage: up to 660V;
Rated Frequency: 50/60Hz;
Rated Current: up to 6300A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 10000 Times;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Air Circuit Breaker;
Orign of Place: Zhejiang, China;
Related Voltage: up to 660V;
Rated Frequency: 50/60Hz;
Rated Current: up to 6300A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 10000 Times;
|