Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Main Switch;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-3;
Rated curret (In): 63A, 80A,100A,125A;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated impulse withstand voltage (Uimp): 6kA;
Electrical life: 4000;
Mechanical life: 20000;
Protection degree: IP20;
Rated making and breaking capacity: 3le, 1.05ue,cosΦ=0.65;
Using the categories: AC-22A;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Installation: Insert;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Conventional Circuit Breaker;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, RCCB, Overcurrent Protection~@~Circuit-Breaker Failure P;
Frame Class: 32A;
Rated Working Voltage: 240V;
Rated Frequency: 50/60Hz;
Rated Working Current: 6,10,16,20,25,32A;
Capacity: 4.5ka / 6ka;
Electric Life: 4000;
Mechanical Life: 8000;
Pole: 1p+N;
Release Type: C;
Residual Operating Current: 30mA,10mA;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Conventional Circuit Breaker;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, RCCB, Overcurrent Protection~@~Circuit-Breaker Failure P;
Frame Class: 32A;
Rated Working Voltage: 240V;
Rated Frequency: 50/60Hz;
Rated Working Current: 6,10,16,20,25,32A;
Capacity: 4.5ka / 6ka;
Electric Life: 4000;
Mechanical Life: 8000;
Pole: 1p+N;
Release Type: C;
Residual Operating Current: 30mA,10mA;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Conventional Circuit Breaker;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, RCCB, Overcurrent Protection~@~Circuit-Breaker Failure P;
Frame Class: 32A;
Rated Working Voltage: 240V;
Rated Frequency: 50/60Hz;
Rated Working Current: 6,10,16,20,25,32A;
Capacity: 4.5ka / 6ka;
Electric Life: 4000;
Mechanical Life: 8000;
Pole: 1p+N;
Release Type: C;
Residual Operating Current: 30mA,10mA;
|