Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ELCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Overcurrent Protection, RCCB;
Standard: IEC 61009-1;
Pole: 1P+N;
Tripping curve: B, C, D;
Rated Current (in): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Mode: Electronic;
Residual Current Type: A, Ac;
Residual Current (LΔn): 30mA, 100mA, 300mA;
Icn: 10kA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
Keyword 1: 63a circuit breaker rcbo;
Keyword 2: RCBO Breaker;
Keyword 3: RCBO;
Keyword 4: residuel current circuit breaker with overcurrent;
|
Breaking Capacity: 3.5ka;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Installation: Insert;
Type: Thermal;
Mounting: Wide Surface Mounting;
Capacity: 2,500A@14VDC25-200A1,500A@48VDC25 200A);
Reset Type: T3,Manual Reset;
Ody: 94V0 Thermoset Plastic;
Voltage: up to 72VDC*;
Rated Current: Max up To200AMP;
Termination: 3/8"Stainless Steel Studs;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage Ue: DC 1000, 1500V;
Rated Insulation Voltage Ui: DC 1600V;
Frame Current: 320, 400, 630u;
Poles: 2/3 Poles;
Tripping: Electromagnetic Tripping+ Thermal Tripping;
Rated Impulse Withstand Voltage Uimp: 12kv;
Ultinate Short-Circuit Breaking Capacity: 20ka;
Ambient Temperature: -35ºC~+70ºC;
Mechanical Durability: 15000/10000/5000;
Electrical Durability: 2000/1500/700;
Standard: IEC/En 60947-2, GB/T 14048.2;
Certificates: CCC, CB, CE, TUV;
Utilization Category: a;
Isolation Function: Have;
Size(L/W/H) mm: 200*80*135(2p), 200*114*135(3p), 270*125*169;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Conventional Circuit Breaker;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection, Circuit-Breaker Failure P;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 500V AC;
ICU: 10ka;
Poles: 1p 2p 3p 4p;
Rated Voltage: 240V;
Rated Working Voltage: Nil:Normal Voltage H:High Voltage;
Ingress Protection: IP40; Wiring Port IP20;
Vibration: Acc. to IEC60068-2-6;
Shocks: Acc. to IEC60068-2-27;
Ambient Temperature: -30°c~70°c;
Elevation: «2000m;
Dimension: 18mm* 68mm*81mm;
Weight: 125.3G;
Pollution Degree: 3;
Tightening Torque of Terminals: 2.0~2.5 N.M;
Installation Method: DIN;
|