Specification |
Application: Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Trade Mark: Dahu;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single or Three;
Operation Condition: Electronic, Instrument, Lighting;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Capacitive Type;
Design Advantage: Clamp on Current Transformer;
Accuracy: 1%;
Primary Current: 0.1-1000A;
Useable Frequency: 10Hz to 100kHz;
Window Size: Check Specification Below;
Maximum Voltage: 600VAC;
Output Signal: Ma/a or Mv/a;
Operating Temp: -10c to +50c;
Maximum Non-Destructive Current: 2000A;
Export Markets: Global;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single or Three;
Operation Condition: Electronic, Instrument, Lighting;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Capacitive Type;
Design Advantage: Clamp on Current Transformer;
Accuracy: 0.5 / 1.0 / 3.0;
Split Core Transformer Input: 5-630A;
Split Core Transformer Output: 0.333 1.5 Output;
Window Size: Check Specification Below;
Rated Frequency: 50-400kHz;
Dielectric Strength: 1000mohms @ 500 VDC;
Operating Temp: -25 C~+75 C;
Internal Structure: Epoxy;
Export Markets: Global;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single or Three;
Operation Condition: Electronic, Instrument, Lighting;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Capacitive Type;
Design Advantage: Clamp on Current Transformer;
Accuracy: 1%;
Primary Current: 0.1-1000A;
Useable Frequency: 10Hz to 100kHz;
Safety: Cat III 600V;
Maximum Voltage: 600VAC;
Output Signal: Ma/a or Mv/a;
Operating Temp: -10c to +50c;
Maximum Non-Destructive Current: 2000A;
Export Markets: Global;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single or Three;
Operation Condition: Electronic, Instrument, Lighting;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Capacitive Type;
Design Advantage: Clamp on Current Transformer;
Accuracy: 1%;
Primary Current: 0.1A-1000A;
Useable Frequency: 10Hz to 100kHz;
Window Size: Check Specification Below;
Maximum Voltage: 600VAC;
Output Signal: Ma/a or Mv/a;
Operating Temp: -10c to +50c;
Maximum Non-Destructive Current: 2000A;
Export Markets: Global;
|