Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 12kv 40.5kv;
Frequency: 50Hz;
Rated Current: 630A-1250A;
Rated Frequency (Hz) Withstand Voltage: 50h/60Hz;
Mechanical Life: 10, 000 Times;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3 Pole;4 Pole;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Current: 63,125,160,200,250,400,630,800,1250,1600A;
Dielectric Property: 2500,3000V;
Rated Current of Frame Size Inm: 63,160,200,250L;
Rated Current of The N Pole: =in;
Rated Insulation Voltage Ui: 400,500,690V;
Uimp Rated Impulse Withstand Voltage: 8000,10000V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Current: 63,125,160,200,250,400,630,800,1250,1600A;
Dielectric Property: 2500,3000V;
Rated Current of Frame Size Inm: 63,160,200,250L;
Rated Current of The N Pole: =in;
Rated Insulation Voltage Ui: 400,500,690V;
Uimp Rated Impulse Withstand Voltage: 8000,10000V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3 Pole;4 Pole;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Current: 1250A;
Dielectric Property: 2500,3000V;
Rated Current of Frame Size Inm: 63,160,200,250L;
Rated Current of The N Pole: =in;
Rated Insulation Voltage Ui: 400,500,690V;
Uimp Rated Impulse Withstand Voltage: 8000,10000V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection;
Rated Voltage: 230V;
|