Hfb100BV Series of Closed-Loop Current Sensors
Min. Order: | 1 Piece |
---|---|
Port: | Shanghai, China |
Payment Terms: | T/T |
Similar Items
You May Like
Product Description
Company Info
Product Description
HFB100BV series of closed-loop current sensors
Closed-loop, AC and DC can be measured, and the working power supply is DC dual power supply, with an output of 0-4V
The HFB100BV series of current sensors are insulated between the primary and secondary stages and are used to measure DC, AC and pulsating currents.
| HFB20BV | HFB25BV | HFB50BV | HFB100BV |
| |
| 20 | 25 | 50 | 100 | A | |
| 40 | 50 | 100 | 150 | A | |
| 1:1000 | 1:1000 | 1:2000 | 1:3000 |
| |
| 20 | 20 | 25 | 35 | Ω | |
| 4±0.5% | V | ||||
| ≤±40 | ≤±30 | mV | |||
|
| ±12 ~±15±0.5% | V | |||
| -20~+85ºC | ≤±1 | mV/ºC | |||
|
| ±0.5 | %FS | |||
| -3db | 0~50 | KHZ | |||
|
| ≤1 | μS | |||
| 50HZ,1min | 3.0 | KV | |||
|
| -20~+85 | ºC | |||
|
| -40~+105 | ºC |
Pin Output: 1, +15V 2, -15V 3, Vout 4, 0V (Power Ground) OFS, Zero Adjustment GIN, Amplitude Adjustment
Lead Output: Red, +15V Blue, -15V Yellow, Vout Black, 0V (Power Ground)
Directions for use
1 When the current to be measured passes through the sensor, the current can be measured at the output. (Note: Incorrect wiring may cause damage to the sensor)