| H1-3K/3.6K/4K/4.6K/5K/6K-S2 |
MODEL | H1-3K-S2 | H1-3.6K-S2 | H1-4K-S2 | H1-4.6K-S2 | H1-5K-S2 | H1-6K-S2 |
DC Input |
Max.PV Array Power [Wp]@STC | 4500 | 5400 | 6000 | 6900 | 7500 | 9000 |
Max.DC Voltage [V] | 600 |
MPPT Voltage Range [V] | 90-550 |
Rated DC Voltage [V] | 360 |
Start Voltage [V] | 120 |
Min.DC Voltage [V] | 80 |
Max.DC Input Current [A] | 12.5/12.5 |
Max.DC Short Circuit Current [A] | 15/15 |
No.of MPPT | 2 |
DC Switch | Integrated |
Battery Parameters |
Battery Type | I ithium battery |
Rated Input Voltage/Voltage Range [V] | 48/42~58.5 |
Rated Charging/Discharging Current [A] | 60/60 | 100/100 |
Charging Mode Control | 3-stages |
AC Output [On-grid] |
Rated AC Power [W] | 3000 | 3680 | 4000 | 4600 | 5000¹ | 6000 |
Max.Apparent Power [VA] | 3000 | 3680 | 4000 | 4600 | 5000 | 6000 |
Rated AC Current [A]@230Vac | 13.1 | 16.0 | 17.4 | 20.0 | 21.8² | 26.1 |
Max.AC Current [A] | 13.6 | 16.7 | 18.2 | 20.9 | 22.7 | 27.3 |
Rated Grid Voltage/Range [V] | 220,230,240/180~280 |
Rated Output Frequency [Hz] | 50/60±5 |
Power Factor [cos φ] | 0.8 leading~0.8 lagging |
Total Harmonic Distortion [THDi] | <3% |
Feed-in | L+N+PE |
AC Output [Back-up Mode] |
Rated Output Power [VA] | 3000 | 4600 | 5000 |
Peak Output Apparent Power [VA] | 3600,10s | 5500,10s | 6000,10s |
Output Voltage [V] | 220/230/240 |
Rated Output Frequency [Hz] | 50/60±5 |
Output THDv (@Liner Load) | <3% |
Ffficiency |
Max Ffficiency | 97.6% |
Furo Efficiency | 97.0% |
Max.Battery Charging Efficiency | 94.6% |
Protection |
AC Short Circuit Protection | Integrated |
Overload Protection | Integrated |
DC Overvoltage/Undervoltage Protection | Integrated |
AC Overvoltage/Undervoltage Protection | Integrated |
AC Overfrequency/Underfrequency | Integrated |
Peak-to-trough Period Setting | Integrated |
Interface |
PV Connection | MC4 |
Battery Connection | Terminal block |
Display | LCD |
Communication | Wi-Fi/Ethernet/4G(Optional) |
General Data |
Operating Temperature Range | -25ºCto+60ºC(45ºCto 60ºC with derating) |
Cooling Method | Natural convection |
Ambient Humidity | 0-100%non-condensing |
Altitude | 4000m(>3000m power derating) |
Noise [dBA] | <29 |
Ingress Protection | IP65 |
Dimensions [H*W*D][mm] | 470*470*190 |
Weight [kg] | 23 |
Warranty [Year] | 5/10/15/20 |
Applicable Standard | IEC62109-1/2,IEC61000-6-1/2/3/4,EN50438,EN50549,C10/C11,IEC62116,IEC61727,RD1699, UNE 206006,UNE 206007,CEI 0-21,AS4777.2,CQC NB/T 32004,VDE-AR-N 4105 |
Remarks:*1 For AS/NZS 4777.2 Rated Output Power is 4999VA. *2 For AS/NZS 4777.2 Rated Output Current is 21.7A. | 13/14 |