Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Economy Model 60 Series;
Installation: Open Frame;
Structure: MCCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC/En60898-1,GB10963.1;
Frame Current(Lm): 63A;
Rated Current(Ln): 6/10/16/20/25/32/40/50/63A;
Rated Operating Frequency: 50/60Hz;
Rated Impulse Voltage(Ui): 500V;
Rated Voltage(Ue): 230V(1p,1p+N),400V(2p-4p,3p+N);
Pole: 1p/1p+N/2p/3p/3p+N/4p;
Rated Impulse Withstand Voltage(Uimp): 4kv;
Rated Short-Circuit Breaking Capacity(IC: 4.5/6ka;
Rated Operating Breaking Capacity(Ics): 4.5/6ka;
Mechanical Life: 10000time;
Electrical Life: 6000time;
Trip Curve: B/C/D;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Arc Extinguishing Chamber;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Overcurrent Protection, Short Circuit Protection;
Current: 1-63A;
Voltage: AC 230V;
Warranty: 2years;
Material: Copper;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
MOQ: 1 Piece;
Delivery Time: 7 Days~30 Days;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Auto Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Multiple Opening/Closing;
Rated Continuous Current: 630/800A;
Rated Duration of Short-Circuit: 3s;
Frequency: 50/60 Hz;
Rated Short-Circuit Breaking Current: 12.5/16ka;
Rated Short-Circuit Making Current: 31.5/40ka;
Rated Lightning Impulse Withstand Voltag: 125/170kv;
Rated Short-Duration P.F. Withstand Volt: 60/70kv;
Line Charging Current: 2/5A;
Cable Charging Current: 10/25/40A;
Max. Interrupting Time / Max.Closing Tim: 10/60ms;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Auto Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, RCCB, Multiple Opening/Closing;
Rated Continuous Current: 630/800A;
Rated Duration of Short-Circuit: 3s;
Frequency: 50/60 Hz;
Rated Short-Circuit Breaking Current: 12.5/16ka;
Rated Short-Circuit Making Current: 31.5/40ka;
Rated Lightning Impulse Withstand Voltag: 125/170kv;
Rated Short-Duration P.F. Withstand Volt: 60/70kv;
Line Charging Current: 2/5A;
Cable Charging Current: 10/25/40A;
Max. Interrupting Time / Max.Closing Tim: 10/60ms;
|