Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Economy Model 60 Series;
Installation: Open Frame;
Structure: RCBO;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC/En61009-1,GB16917.1;
Frame Current(Lm): 40A;
Rated Current(Ln): 6/10/16/20/25/32/40A;
Rated Operating Frequency: 50/60Hz;
Rated Impulse Voltage(Ui): 400V;
Rated Voltage(Ue): 230;
Pole: 1p+N;
Rated Impulse Withstand Voltage(Uimp): 4kv;
Rated Short-Circuit Breaking Capacity(IC: 6/10ka;
Mechanical Life: 20000time;
Electrical Life: 6000time;
Trip Curve: B/C/D;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Withdrawable;Fixed;
Structure: Vcb;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 12kv;
Rated Current: 630/1250/1600/2000/2500/3150A;
Switching Operations of Short Circuit Cu: 50 Cycles;
Mechanical Endurance: 30000 Cycles;
Breaking Operations of Rated Current: 20000 Cycles;
Weight: 120~150kg;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Insert;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Rated Voltage: 12kv;
Rated Current: 630;1250;1600;2000;2500;3150A;
Distance Between Phases: 210,275mm;
Mechanism Type: Permanent Magnetic;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Withdrawable;
Structure: Vcb;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Current: 630/1250/1600/2000/2500/3150A;
Rated Voltage: 24kv;
Rated Frequency: 50Hz;
Insulated Cylinder: Embedded Poles;
Phase Spacing: 275mm;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electronic Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 2/4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, RCCB;
|