Specification |
Application: Power, Electronic, Instrument, Lighting;
Phase: Three;
Core: Shell-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Separated Winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EE;
Brand: Abilkeen;
Product Name: Distribution Transformer;
Primary Voltage: 6.3kv, 10kv, 11kv, 15kv;
Secondary Voltage: 0.4kv/0.415kv/0.433kv;
Rated Capacity: Rated Capacity;
Standard: IEC60076, GB1094-1996; Jb/T10088-2004; GB/T6451-20;
Vector Group: Vector Group;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou;
Rated Capacity: 50-31500 kVA;
H.V. Winding: 35kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio, Wind Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou;
Rated Capacity: 50-31500 kVA;
H.V. Winding: 15kv 25kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Rated Capacity: 50-31500 kVA;
High Voltage: 11kv;
Low Voltage: 0.4kv/0.415kv;
Ambient Temperature: 40ºC -+ 40ºC;
No-Load Loss: 0.17-3.24kw;
Load Loss: 0.71-17.7kw;
Frequency: 50Hz/60Hz;
Connection Group: Dyn11 Yyn0;
|