Specification |
Theory: Pressure Steam;
Type: Pressure Steam Sterilization Equipments;
Electric Tension: 380V;
LCD Display: With LCD Display;
Ultra High Temperature Alarm: Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Sterilize Temperature, Sterilize Time;
Material: AISI316L/304 for Option;
Name: Pulse Vacuum Steam Sterilizer;
Application: Garments, Surgical Instrument, Tools, Liquids;
Steam Supply: Built-in Steam Generator or External Steam Source;
Model: Mdd-0.25,0.36,0.6,0.8,1.0,1.2,1.5,2.0;
Loading Capacity: 250L,360L,600L,800L,1000L,1200L, 1500L...4000L;
Door: Single/Pass-Through Double Doors;
Terms of Payment: T/T, L/C;
Customized: Available;
|
Theory: Gas Sterilizer;
Type: Gas Sterilization Equipments;
Electric Tension: 380V;
LCD Display: With LCD Display;
Ultra High Temperature Alarm: Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Sterilization Information Recording and Printing;
Material: Stainless Steel;
Rated Power: 12kw;
Work Pressure: 0kpa-60kpa;
Working Humidity: 30‰-80‰;
Operating Temperature: 30ºC-50ºC;
Sterilization Time: 3‐99h;
Liner Material: 304 Stainless Steel;
Outer Box: 304 Stainless Steel;
Disabled Times: 0-50 Times Adjustable;
Double Protective Door: Yes;
Sterilization Purpose: Sterilize Items That Are Not Resistant to Temperat;
Sterilization Method: Mixed Ethylene Oxide Gas;
Action Valve: Pneumatic Valve;
Heating Method: Electric Heating Film for Uniform Heating;
Performance Description: Negative Pressure Working System;
Way to Control: PLC Automatic Control Liquid Crystal Display Worki;
|
Theory: Autoclave;
Type: Pressure Steam Sterilization Equipments;
Electric Tension: AC220V/110V 10%;50/60Hz;
LCD Display: LED Display;
Ultra High Temperature Alarm: Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Sterilization Information Recording and Printing;
Material: Stainless Steel;
Designed Pressure: 0.25MPa;
Rated Working Pressure: 0.22MPa;
Sterilization Temperature: 116~134 Degree;
Design Temperature: 139 Degree;
Capacity: 75L;
Drying Tim: 0~240min;
Sterilization Time Range: 4~120 Min;
|
LCD Display: Without LCD Display;
Ultra High Temperature Alarm: Without Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Without Sterilization Information Recording and Printing;
Material: ABS Material;
Item Number: Cka-138;
Working Current: 30mA;
Main Material: Plastic;
Battery Specifications: 4*AAA Battery;
Product Name: Oximeter;
Weight: 38.9g;
Safety Standard: GB/T18830-2009;
Measuring Method: Pulse Scanning/Oscilloscope Assay;
Voltage: 6V;
Pressure Accuracy: ±0.4kpa(±3mmhg);
Pulse Range: 40-199 Times/Min;
Wrist Band Display Range: 0-39.9kpa(0-299 Mmhg);
Pressure Range: 0-37.3kpa(0-280mmhg);
Bluetooth: Need Customization;
Display Method: TFT Display;
|
Theory: Autoclave;
Type: Pressure Steam Sterilization Equipments;
Electric Tension: AC220V/110V 10%;50/60Hz;
LCD Display: With LCD Display;
Ultra High Temperature Alarm: Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Sterilization Information Recording and Printing;
Material: Stainless Steel;
Designed Pressure: -0.1~0.25MPa;
Working Pressure: 0.225MPa;
Working Temperature: 105-136 Degree;
Design Temperature: 139 Degree;
Capacity: 300 L;
Vacuum: -0.086MPa;
|