Specification |
Theory: Pressure Steam;
Type: Pressure Steam Sterilization Equipments;
Electric Tension: 380V;
LCD Display: With LCD Display;
Ultra High Temperature Alarm: Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Sterilize Temperature, Sterilize Time;
Material: AISI316L/304 for Option;
Name: Pulse Vacuum Steam Sterilizer;
Application: Garments, Surgical Instrument, Tools, Liquids;
Steam Supply: Built-in Steam Generator or External Steam Source;
Model: Mst-50,60,80,100,120,135,150,185,200,300,450;
Loading Capacity: 60L,80L,100L,120L,135L,150L, 185L,200L,300L,450L;
Door: Single/Pass-Through Double Doors;
Terms of Payment: T/T, L/C;
Customized: Available;
|
Type: Pressure Steam Sterilization Equipments;
Electric Tension: 220V;
LCD Display: With LCD Display;
Ultra High Temperature Alarm: Ultra High Temperature Alarm;
Material: Stainless Steel;
Working Pressure: 0.22MPa;
Max. Working Pressure: 0.23MPa;
Working Temperature: 134ºC;
Heat Average: ≤±1ºC;
Timer Range: 0-99min/0-99hour59min;
Temperature Adjust Range: 105-134ºC;
Power: AC220V 50Hz;
|
Theory: Pressure Steam;
Type: Pressure Steam Sterilization Equipments;
Electric Tension: 220V;
LCD Display: With LCD Display;
Ultra High Temperature Alarm: Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Sterilization Information Recording and Printing;
Material: Stainless Steel;
Model: Bk-B-600;
Circulating Air: ≥600m3/H;
Noise: ≤50dB;
O3 Residue: ≤0.0074mg/M3;
Applicable Room: ≤60m3;
Ultraviolet Leakage: ≤5μw/Cm2;
Temp.Range: -10~40;
Humidity: ≤80%;
Atmosphere Pressure: 60kpa~106kpa;
Consumption: ≤350W;
Power Supply: AC110/220V±10%, 50/60Hz;
External Size(W*D*H)mm: 540*420*900;
Packing Size(W*D*H)mm: 580*490*90;
Gross Weight(Kg): 22;
|
LCD Display: Without LCD Display;
Ultra High Temperature Alarm: Without Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Without Sterilization Information Recording and Printing;
Power Supply Mode: Built in Battery;
Working Current: 30mA;
Main Material: Plastic;
Battery Specifications: 4*AAA Battery;
Product Name: Oximeter;
Weight: 38.9g;
Safety Standard: GB/T18830-2009;
Measuring Method: Pulse Scanning/Oscilloscope Assay;
Voltage: 6V;
Pressure Accuracy: ±0.4kpa(±3mmhg);
Pulse Range: 40-199 Times/Min;
Wrist Band Display Range: 0-39.9kpa(0-299 Mmhg);
Pressure Range: 0-37.3kpa(0-280mmhg);
Bluetooth: Need Customization;
Display Method: TFT Display;
|
Theory: Autoclave;
Type: Pressure Steam Sterilization Equipments;
Electric Tension: 220V&110V;
LCD Display: With LCD Display;
Ultra High Temperature Alarm: Ultra High Temperature Alarm;
Sterilization Information Recording and Printing: Sterilization Information Recording and Printing;
Material: Stainless Steel;
Volume: 35L,50L;
Working Temperature: 134ºC;
Temperature Adjust Range: 105-134ºC;
Timer Range: 0-99min;
|