Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 2/3/4p;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
Standard: IEC 60947-2;
Pole: 3 Pole;
Rated Current (in): 100A,125A,150A,175A,200A,225A, 250A;
item: Molded case circuit breakers;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Insulation Voltage (Ui): 1250V;
Rated Service Voltage (Ue): 15V-1200V;
Rated Current (in): 6A-63A;
Short-Circuit Breaking Capacity (Ics = I: 6ka;
Mechanical Life: 8500 Operations;
Electrical Life: 1500;
Trip Characteristics: B / C Type;
Ingress Protection: IP40 (Body); IP20 (Terminal);
Ambient Temperature Range (Service): -30ºC ~ 70ºC;
Standards Compliance: IEC 60947-2 GB/T 14048.2;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Open Frame;
Structure: ACB;
Poles Number: 3;
Type: High Voltage;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Single Gross Weight: 100.000kg;
Selling Units: Single Item;
Packaging Details: Each One in a Wood Box;
Single Package Size: 100X100X100cm;
Supply Ability: 300 Piece/Pieces Per Month;
Rated Voltage: Other;
Bcd Curve: B;
Rated Frequency: 50/60Hz;
Rated Current: 1000A;
Frequency: 50/60Hz;
Pole No.: 3;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|