Earthed Voltage Transformer
US$60.18-98.09 / Set
View
  • Recommend for you
  • What is La-10 5-40A 0.2-0.5/10p 10/15va Indoor Semi-Enclosed Through-Wall High Voltage Current Transformer
  • What is Gw9 12/15kv New Ceramic Type Outdoor Isolation Knife Switch Disconnecting Switch
  • What is Kdc Three-Phase Pad Mounted Transformer Kiosk Substation Compact Substation

What is Jdj2 35kv 35000/100V 0.2/6p 80-500va Outdoor Hv Oil-Immersed Insulation Voltage Instrument Transformer Mutual Inductor

About this Item
Details
Company Profile

Price

Min. Order Reference FOB Price

1 Set US$60.18-98.09 / Set

Sepcifications

  • Application Electronic, Instrument, Power System
  • Type Voltage Transformer
  • Phase Single
  • Operation Condition Outdoor
  • Usage Protection, Measurement
  • Winding Form Small Fixed Type
  • Insulating Medium Insulating Oil
  • Installation Strut Type
  • Magnetic Circuit Structure Single Stage Type
  • Voltage Transformation Principle Electromagnetic Type
  • Transport Package Wooden Case
  • Specification 500*394*980mm
  • Trademark CNKC
  • Origin China
  • Rated Transformation Ratio 35000/100V
  • Accuracy Class Combination 80-600va
  • Thermal Limiting Output 1000-1200va
  • Rated Insulation Level 40.5/95/185kv
  • Rated Frequency 50/60Hz
  • Rated Voltage 35kv

Product Description

Product Description JDJ2-35(38.5) model Potential Transformer is one-phase double-winding,oil-impregnated type outside product, suitable to be used at A.C.50Hz power line with rated voltage 35(38.5)KV for voltage &energy measuring and relay protection of associated equipments. This model ...

Learn More

Earthed Voltage Transformer Comparison
Transaction Info
Price US $ 60.18-98.09/ Set US $ 75.30-150.69/ Set US $ 50.79-91.38/ Set US $ 68.39-88.00/ Set US $ 46.80-83.09/ Set
Min Order 1 Sets 1 Sets 1 Sets 1 Sets 1 Sets
Trade Terms - - - - -
Payment Terms L/C, T/T, D/P L/C, T/T, D/P L/C, T/T, D/P L/C, T/T, D/P L/C, T/T, D/P
Quality Control
Management System Certification ISO 9001, ISO 14001 ISO 9001, ISO 14001 ISO 9001, ISO 14001 ISO 9001, ISO 14001 ISO 9001, ISO 14001
Trade Capacity
Export Markets North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Annual Export Revenue - - - - -
Business Model OEM, ODM OEM, ODM OEM, ODM OEM, ODM OEM, ODM
Average Lead Time - - - - -
Product Attributes
Specification
Application: Electronic, Instrument, Power System;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Insulating Oil;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Transformation Ratio: 35000/100V;
Accuracy Class Combination: 80-600va;
Thermal Limiting Output: 1000-1200va;
Rated Insulation Level: 40.5/95/185kv;
Rated Frequency: 50/60Hz;
Rated Voltage: 35kv;
Application: Electronic, Instrument, Power System;
Type: Combined Instrument Transformers Measuring Box;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Insulating Oil;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Current Ratio: 5-300A;
Rated Primary Voltage: 35000V;
Rated Insulation: 40.5/95/185kv;
Rated Voltage: 35kv;
Rated Frequency: 50/60Hz;
Rated Secondary Voltage: 100V;
Rated Voltage Load: 0.2-50va;
Rated Current Load: 0.2-20va;
Power Frequency Withstand Voltage: 10.5kv;
Application: Electronic, Instrument, Power System;
Type: Combined Instrument Transformers Measuring Box;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Primary Current: 7.5-1000A;
Rated Frequency: 50/60Hz;
Rated Voltage: 35kv 10kv 6kv;
Accuracy Level: 0.5 and 0.2, 0.5s and 0.2s;
Rated Transformation Ratio: Voltage Ratio: 6000/100V 10000/100V;
Univariate Ratio: 7.5-1000;
Rated Secondary Output: 10-15va;
One Second Thermal Stability Current: 1.0-80ka;
Dynamic Stable Current: 2.5-100ka;
Max Output: 2*400va;
Rated Insulation Level: 7.2-75kv;
Single Transformer Ratio: 7.5-1000;
Application: Electronic, Instrument, Power System;
Type: Combined Instrument Transformers Measuring Box;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Insulating Oil;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Primary Current: 5-1000A;
Rated Voltage Ratio: 10000/100V,6000/100V;
Rated Voltage: 10kv;
Rated Frequency: 50/60Hz;
Rated Secondary Current: 5A or 1A;
Accuracy Level: 0.2s,0.2,0.5s;
Rated Capacity: Voltage Part: 0.2 Class, 20va;
Rated Capacity:Current Part: 0.2s, 0.2 Class, 10va;
Rated Short-Time Thermal Current Multipl: 100I1n/1s;
Rated Short-Time Dynamic Stability Multi: 250I1n;
Rated Secondary Output: 10va;
Rated Short Time Thermal Current: 1.5-80ka;
Rated Dynamic Stable Current: 2.5-100ka;
Application: Electronic, Instrument, Power System;
Type: Combined Instrument Transformers Measuring Box;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Primary Current: 7.5-1000A;
Rated Frequency: 50/60Hz;
Rated Voltage: 35kv 10kv 6kv;
Accuracy Level: 0.5 and 0.2, 0.5s and 0.2s;
Rated Transformation Ratio: Voltage Ratio: 35000/100V, 10000/100V, 6000/100V;
Univariate Ratio: 7.5-1000;
Rated Secondary Output: 10-15va;
One Second Thermal Stability Current: 1.0-80ka;
Dynamic Stable Current: 2.5-100ka;
Supplier Name

ZHEJIANG KANGCHUANG ELECTRIC CO.,LTD

China Supplier - Diamond Member Audited Supplier

ZHEJIANG KANGCHUANG ELECTRIC CO.,LTD

China Supplier - Diamond Member Audited Supplier

ZHEJIANG KANGCHUANG ELECTRIC CO.,LTD

China Supplier - Diamond Member Audited Supplier

ZHEJIANG KANGCHUANG ELECTRIC CO.,LTD

China Supplier - Diamond Member Audited Supplier

ZHEJIANG KANGCHUANG ELECTRIC CO.,LTD

China Supplier - Diamond Member Audited Supplier