Specification |
After-sales Service: Local Network;
Warranty: 1 Year;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Model: 500GF17-2;
Diesel Engine Model: G12V190zld1-2;
Alternator Model: 1FC6456-6la4;
Rated Power (Kw): 500;
Rated Voltage (V): 400/230;
Rated Frequency (Hz): 50/60;
Voltage Steady-State Adjusting Rate (%): ±2.5;
Voltage Transient-State Adjusting Rate (: -15~+20;
Voltage Stable Time (S): 1.5;
Voltage Fluctuation Rate (%): 0.5;
Voltage Regulation Range (%): 95-105;
Frequency Steady-State Adjusting Rate: 5%;
Frequency Transient-State Adjusting Rate: ±10%;
Frequency Stable Time (S): 7;
Frequency Fluctuation Rate (%): 0.5;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Engine: Cummis;
Alternator: Mecc Alte, Stamford, Leroy Somer, Marathon;
Controller: Deep Sea, Comap, Smartgen;
Frequency: 50Hz;
Per Speed: 1500rpm;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Engine: Cummis;
Alternator: Mecc Alte, Stamford, Leroy Somer, Marathon;
Controller: Deep Sea, Comap, Smartgen;
Frequency: 50Hz;
Per Speed: 1500rpm;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Engine: Cummis;
Alternator: Mecc Alte, Stamford, Leroy Somer, Marathon;
Controller: Deep Sea, Comap, Smartgen;
Frequency: 50Hz;
Per Speed: 1500rpm;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Engine: Cummis;
Alternator: Mecc Alte, Stamford, Leroy Somer, Marathon;
Controller: Deep Sea, Comap, Smartgen;
Frequency: 50Hz;
Per Speed: 1500rpm;
|