Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Arc Chamber;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-2, GB14048-2;
Rated curret (In): 80A,100A,125A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Open Frame;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Rated Current a: 630/1250/1600/2000;
Rated Short-Circuit Breaking Current Ka: 20/25/31.5;
Mechanical Endurance: M2 Class;
Rated Voltage: 40.5kv;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 1000V;
Max Current: 63A;
Enclosure Box: with/Without;
Rated Current: 6A, 10A, 16A, 20A, 32A, 40A, 63A;;
Imp: 6ka/10ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p-4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Poles: 1pole, 2pole, 3pole, 4pole;
Frequency: 50/60Hz;
Rated Current in(a): 6, 10, 16, 20, 25, 32, 40, 50, 63;
Rated Insulated Voltage Ui(V): 400;
Rated Working Voltage Ue(V): 240/415V;
Instantaneous Trip Type: H;
Breaking Capacity(a): 6ka;
Mechanical Life(Times): 20000;
|