Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Arc Chamber;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Cover: BMC Unflaming Material;
Base: BMC Unflaming Material;
Terminal: with Terminal Box;
Neutral Pole: Left Side;
Rated Insulation Voltage: 1000V;
Rated Operation Voltage: 400/415V;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Withdrawable;
Structure: Vcb;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Current: 630/1250/1600/2000/2500/3150A;
Rated Voltage: 24kv;
Rated Frequency: 50Hz;
Insulated Cylinder: Embedded Poles;
Phase Spacing: 275mm;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p, 2p, 3p,4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Pole Number: 1p, 2p, 3p,4p;
Rated Voltage(V): AC 2p 230/240V 4p400/415V;
Rated Current in: 16,25,40,63,80,100A;
Rated Residual Operating Current (Ma): 30,100,300,500mA;
Protection: Ground Fault;
Protection Degree: IP20;
Type of Trip: Electro-Magnetic Release;
Type of Terminal: Lug Type and Pin Type;
Standard: En/IEC61008-1;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3p, 4p;
Type: Circuit Breaker;
Rated Current of Frame(a): 125, 160, 250, 400, 630, 800;
Rated Operating Voltage(V): 400, 690;
Rated Frequency(Hz): 50;
Poles: 3, 4;
Standard: IEC60947-2;
Rated Insulation Voltage Ui (V): 800;
Rated Impulse Withstand Voltage Uimp: 8;
Thermo Adjustable Setting in: 0.8/0.9/1.0 in;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3p, 4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Shell Frame Rated Current Inm (a): 2000,3200,4000,6300;
ICU(Ka)O-Co: 80,100,120;
Rated Short-Circuit Capacity: 105/0.25,143/0.2,165/0.2;
Rated Running Short Circuit Breaking Cap: 50,60,80,100;
Standard: IEC60947-2;
Rated Impluse Withstand Voltage Uimp (Kv: 8;
Fixed Magnetic Trip: Has This Option;
|