Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 1p, 2p, 3p, 4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Shell Current(a): 100,225,400,638(800);
Rated Current(a): 10,16,20,32,40,50,63,80,;
Rated Insulated Voltage(V): 690;
Rated Voltage(V): 400;
Rated Impluse Withstand Voltage Uimp(Kv): 8;
Mechanical Endurance: 8500;
Electrical Endurance: 1500;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 2,4;
Type: Residual Current;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Current in: 16, 25, 32, 40, 50, 63, 80, 100;
Terminal Connection Type: Cable/Pin-Type Busbar;
Leakage Type: Electromagnetic Type;
Insulation Voltage Ui: 500;
Rated Voltage Ue: 230/400;
Rated Frequency: 50/60;
Connection: From Top and Bottom;
Poles: 2, 4;
Rated Breaking Capacity Inc: 6000, 10000;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p,2p,3p,4p;
Type: Mini;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Frequency (Hz): 50/60;
Terminal Connection Type: Cable/Pin-Type Busbar/U-Type Bar;
Rated Breaking Capacity: 6000,10000;
Insulation Voltage Ui (V): 500;
Rated Voltage Ue (V): 240/415;
Connection: From Top and Bottom;
Electrical Life (T): 6000;
Poles: 1,2,3,4;
Rated Current in (a): 1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p,2p,3p,4p;
Type: Mini;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Frequency (Hz): 50/60;
Terminal Connection Type: Cable / Pin-Type Busbar;
Insulation Voltage Ui (V): 500;
Rated Breaking Capacity (a): 4500,6000;
Rated Voltage Ue (V): 230/400;
Connection: From Top and Bottom;
Electrical Life (T): 6000;
Poles: 1,2,3,4;
Rated Current in (a): 1,2,4,6,10,16,20,25,32,40,50,63;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p+N;
Type: Mini;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Mechanical Life: 10000;
Terminal Connection Type: Cable/Pin-Type Busbar;
Rated Breaking Capacity: 3000;
Insulation Voltage Ui (V): 500;
Rated Voltage Ue (V): 240/415;
Connection: From Top and Bottom;
Electrical Life (T): 4000;
Poles: 1p+N;
Rated Current in (a): 6, 10, 16, 20, 25, 32;
|