Specification |
Application: Power, Electronic, Instrument, Lighting;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Separated Winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: OD;
OEM: Avaliable;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Oil Immersed Tranformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Power Transformer;
Reference Standards: IEC 60076;
Capacity: 6300~180000kVA;
Rated H. V.: 110kv;
Rated L. V.: 6.3-11kv;
Cooling Way: Onan/Onaf;
Impedance: as Per IEC Standard;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
AC Withstand Voltage: as Per IEC Standard;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Oil Immersed Tranformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Power Transformer;
Reference Standards: IEC 60076;
Capacity: 6300~180000kVA;
Rated H. V.: 110kv;
Rated L. V.: 6.3-11kv;
Cooling Way: Onan/Onaf;
Impedance: as Per IEC Standard;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
AC Withstand Voltage: as Per IEC Standard;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 800~31500kVA;
Rated H. V.: 35kv± 2× 2.5%;
Rated L. V.: 6.3 (10.5, 11) Kv;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 800~31500kVA;
Rated H. V.: 35kv± 2× 2.5%;
Rated L. V.: 6.3 (10.5, 11) Kv;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|