Specification |
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: OD;
Brand: Golden Triangle;
Efficiency: High Efficiency;
Production: Customer Made;
Losses: Low Losses;
Rated Capacity: 30-2500kVA;
High Voltage: 6, 6.3, 6.6, 10, 10.5, 11;
Tap Range: +-2*2.5, +-5;
|
Application: Power;
Phase: Single/Three Phases;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Separated Winding Transformer;
Usage: Rectifier Transformer, Power Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: Strip Silicon Iron Sheet;
Brand: Domestic Private Brand;
Connection Group: II,Dy,Yd,D/Double The Star,Y/Double The Star;
Impedance Voltage: 2%-8%;
Efficiency: >98%;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Reference Standards: IEC 60076;
Voltage (Hv) (Kv): 11 Kv;
Core Material: Silicon Steel;
Temperature Rise (W): 60/65K;
Insulation Class: a-Class;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
Rated Capacity: 500 kVA;
Cooling Way: Onan/Onaf;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Reference Standards: IEC 60076;
Voltage (Hv) (Kv): 11 Kv;
Core Material: Silicon Steel;
Temperature Rise (W): 60/65K;
Insulation Class: a-Class;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
Rated Capacity: 500 kVA;
Cooling Way: Onan/Onaf;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Reference Standards: IEC 60076;
Voltage (Hv) (Kv): 11 Kv;
Core Material: Silicon Steel;
Temperature Rise (W): 60/65K;
Insulation Class: a-Class;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
Rated Capacity: 500 kVA;
Cooling Way: Onan/Onaf;
|