Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Insulating Paper;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rate Current: 400A;
Output: 5A;
Coil Ratio: 1:80;
Accuracy: 0.5class;
Internal Size: 80*80mm;
|
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Key Words: High Current Transformers;
Accuracy: 0.5s, 0.5%, 1%, 3%;
Rated Voltage: 35kv;
Range of Primary Rated Current: 100-1500A;
Range of Rated Load: ≤10va;
Rated Frequency: 50/60Hz;
Rated Secondary Current: 5A or 1A;
Aperture (mm): Φ55;
Output Signal: 1A, 5A, 333mv, 1V or 5V(Customized);
Model: High Frequency Current Transformer;
|
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Key Words: High Voltage CT;
Accuracy: 0.5%, 1%;
Rated Voltage: 35kv;
Range of Primary Rated Current: 300-1500A;
Range of Rated Load: ≤25va;
Rated Frequency: 50/60Hz;
Rated Secondary Current: 5A or 1A;
Aperture (mm): Φ185;
Model: Hobut Split Core CT;
Weight (Kg): 4.5;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006; an;
Accuracy Class: 0.5s, 0.5%, 1%, 3%;
Range of Primary Rated Current: 100-1500A;
Range of Rated Load: ≤10va;
Rated Frequency: 50/60Hz;
Rated Secondary Current: 5A or 1A;
Safety Factor Rating: (Fs) <10;
Output Signal: 1A, 5A, 333mv, 1V or 5V(Customized);
Cable Length: 2.5m, 5m, 10m(Customized);
Weight (Kg): 2;
|
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Ratio: 1000: 1 or 2000:1 , Customized;
Key Words: High Current Transformer 200 AMP;
Accuracy Class: 0.2%, 0.5 %, 1%;
Key Word: Indoor Low Voltage Transformer;
Model: High Frequency Current Transformer Price;
System Voltage: 720V(0.72kv);
Frequency Range: 40 Hz-500 Hz;
Max. Jaw Opening: 16 mm;
Weight (G): 60;
Color: Black or Customized;
|