Specification |
Application: Power, Electronic;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: Ring;
Brand: Hengda;
Connection Group: Yyn0 or Dyn11;
Impedance: 4%-6%;
Input Voltage: 10kv, 11kv, 15kv, 22kv, 30kv,33kv,35kv;
Output Voltage: 400V;
Tap Range: ±5% or ± 2*2.5%;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 2500kVA;
High Voltage: 11kv;
Low Voltage: 0.4kv;
Impedance Voltage: 5%;
No-Load Loss: 2.29kw;
Load Loss: 2.12kw;
No-Load Current: 0.4%;
Frequency: 50/60Hz;
Connection Method: Yyn0/Dyn11;
Material: Aluminum/Copper;
Weight: 5500kg;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 2500kVA;
High Voltage: 11kv;
Low Voltage: 0.4kv;
Impedance Voltage: 5%;
No-Load Loss: 2.29kw;
Load Loss: 2.12kw;
No-Load Current: 0.4%;
Frequency: 50/60Hz;
Connection Method: Yyn0/Dyn11;
Material: Aluminum/Copper;
Weight: 5500kg;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier;
Phase: Three;
Core: Shell-type Transformer;
Cooling Method: Dry-type Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Capacity: 5kVA—500kVA;
Output Voltage: 5kv-300kv;
Voltage Accuracy: ±0.5;
Current Accuracy: ±0.5;
Data Storage: 60 Groups;
Language: Can Be Customized;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 2500kVA;
High Voltage: 11kv;
Low Voltage: 0.4kv;
Impedance Voltage: 5%;
No-Load Loss: 2.29kw;
Load Loss: 2.12kw;
No-Load Current: 0.4%;
Frequency: 50/60Hz;
Connection Method: Yyn0/Dyn11;
Material: Aluminum/Copper;
Weight: 5500kg;
|