Specification |
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou Electric;
High Voltage: 33kv;
Low Voltagewinding: 0.4kv 0.415kv;
Frequency: 50Hz/60Hz;
Rated Capacity: 50-31500 kVA;
Connection Group: Dyn11;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
Ambient Temperature: -40ºC -+ 40ºC;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 1000kVA or Customized;
Rated H. V.: 15kV or Customized;
Rated L. V.: 0.4kV or Customized;
Impedance: 4~6 %;
Cooling Way: AN/AF;
Winding Material: Copper;
Core Materials: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: As Standard;
Enclosure: IP21 or Customized;
Accessories: Fans, Enclosure;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hero;
Rated Capacity: 500kVA;
Rated Voltage Ratio: 35kv/0.4kv;
Impedance Voltage: 6.5;
No Load Loss: 690W;
on Load Loss: 6590W;
Weight: 2620kg;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 30kVA;
High Voltage: 10/11kV;
Low Voltage: 0.4kV;
Tapping Range: +-2x2.5%;
Impedance Voltage: 4%;
No-Load Loss: 0.1kW;
Load Loss: 0.63/0.6kW;
No-Load Current: 1.5%;
Frequency: 50/60Hz;
Connection Group: Yyn0/Dyn11;
Coil Material: Aluminum/Copper;
Weight: 400kg;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 30kVA;
High Voltage: 10/11kV;
Low Voltage: 0.4kV;
Tapping Range: +-2x2.5%;
Impedance Voltage: 4%;
No-Load Loss: 0.1kW;
Load Loss: 0.63/0.6kW;
No-Load Current: 1.5%;
Frequency: 50/60Hz;
Connection Group: Yyn0/Dyn11;
Coil Material: Aluminum/Copper;
Weight: 400kg;
|