Specification |
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Transformer Type: Dry Type Power Distribution Transformer;
Application Scenario: Wind Turbine Generator;
Rated Capacity: 630~4000kVA;
Rated Voltage(Hv/LV): 34.5/0.69kV (Customized);
Frequency: 50/60Hz;
Impedance: 4~8%;
Tapping Range: +2X2.5%/-2X2.5%;
Vector Group: Dyn11/Yyn0/Other;
Winding Material: Copper/Aluminium;
Core Materials: Silicon Steel/Amorphous Alloy;
Insulation Level: as Per IEC Standard;
Temperature Rise: 125K;
Accessories: Cooling Fans, Enclosure ,Temperature Control;
Optional Protective Enclosure: IP00/IP20/IP23/Cutomized;
Applied Standards: GB/T10228, GB1094.11, IEC60076-11, DIN42523;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Capacity: 3150kVA;
Rated H. V.: 11kV;
Rated L. V.: 0.4kV;
Impedance: 4~8% or Customized;
Insulation Level: IEC Standard;
Reference Standards: IEC Standard;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Transformer Type: Cast Resin Dry Type Transformer;
Rated Capacity: 2000kVA or Customized;
Rated Voltage(Hv/LV): 34.5/0.48kV;
Frequency: 50 Hz;
Impedance: 4~6%;
Tapping Range: +2X2.5%/-2X2.5%;
Cooling Way: AN/AF;
Vector Group: Dyn11;
Winding Material: Copper;
Core Materials: Silicon Steel;
Insulation Level: as Per IEC Standard;
Temperature Rise: Customized;
Accessories: Fans, Enclosure;
Optional Protective Enclosure: IP00/IP20/IP23/Cutomized;
Applied Standards: GB/T10228, GB1094.11, IEC60076-11, DIN42523;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 3000kVA;
Rated H. V.: 11kV;
Rated L. V.: 0.4kV;
Impedance Voltage: 4~6 %;
Frequency: 50Hz/60Hz;
Cooling Way: ONAF/ONAN;
Tapping Range: +2X0.25% /-2X0.25%/Customized;
Core Material: Silicon Steel;
Winding Material: Copper;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 2500kVA;
Rated H. V.: 10kV;
Rated L. V.: 0.4kV;
Impedance Voltage: 4~6 %;
Frequency: 50Hz/60Hz;
Cooling Way: ONAF/ONAN;
Tapping Range: +2X0.25% /-2X0.25% /Customized;
Core Material: Silicon Steel;
Winding Material: Copper;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|