Specification |
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 800~25000kVA;
Rated H. V.: 35kv;
Rated L. V.: 0.4kv;
Impedance: 4 %;
Cooling Way: an/Af;
Winding: Cooper/Aluminum;
Core Material: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Enclosure: IP20/IP23;
Accessories: Fans, Enclosure;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Three-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: PEARL ELECTRIC;
Production Descriptions: Cast Resin/Dry type Power Distribution Transformer;
Reference Standards: IEC/GB/GBT/AS/TNB/DIN(Customized);
Field of Application: indoor;
Capacity: 3150kVA;
Voltage (HV/LV): 15/0.4kv;
Impedance: 6~8%;
Connections (Vector Group): Dyn11/YNd11;
Frequency: 50Hz/60Hz;
Tapping Range: +/-2 x 2.5%(Customized), NLTC/OLTC;
Core materials: Silicon Steel;
Winding materials: Copper;
Noise Level: As per IEC Specifications;
Insulation Class: H-Class/F-Class(Customized);
Temperature Rise: 125K;
Cooling Way: AN/AF;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Three-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: PEARL ELECTRIC;
Production Descriptions: Cast Resin/Dry type Power Distribution Transformer;
Reference Standards: IEC/GB/GBT/AS/TNB/DIN(Customized);
Field of Application: indoor;
Capacity: 2000kVA;
Voltage (HV/LV): 34.5/0.4kv;
Impedance: 6~8%;
Connections (Vector Group): Dyn11/YNd11;
Frequency: 50Hz/60Hz;
Tapping Range: +/-2 x 2.5%(Customized), NLTC/OLTC;
Core materials: Silicon Steel;
Winding materials: Copper;
Noise Level: As per IEC Specifications;
Insulation Class: H-Class/F-Class(Customized);
Temperature Rise: 125K;
Cooling Way: AN/AF;
|
Application: Power, Electronic;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Transformer Type: Dry Type Transformer;
Capacity: 1250KVA;
Primary Voltage / Secondary Voltage: 10kV;
Frequency: 50/60Hz;
Tapping Range: +2X2.5%/-2X2.5%;
Impedance: 4~8%;
Application Scenario: Photovoltaic Power System;
Vector Group: Dyn11 or Yyn0 (Customized);
Winding Material: Copper/Aluminium;
Core Materials: Silicon Steel;
Insulation Material: Cast Resin;
Temperature Rise: 125K;
Accessories: Cooling Fans, Enclosure, Temperature Control;
Optional Protective Enclosure: IP00/IP20/IP23/Cutomized;
Applied Standards: GB/T6451, GB1094, IEC60076;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Amorphous Alloy Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Offshore Drilling Rig Power Transmission;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Transformer Type: Dry Type Amorphous Transformer;
Application Scenario: Offshore Drilling Rig Power Transmission;
Capacity: 2000KVA;
Primary Voltage / Secondary Voltage: 69/0.44kV;
Frequency: 50/60Hz;
Tapping Range: +2X2.5%/-2X2.5%;
Impedance: 4~8%;
Vector Group: Dyn11 or Yyn0 (Customized);
Winding Material: Copper/Aluminium;
Core Materials: Amorphous Alloy;
Insulation Material: Cast Resin;
Temperature Rise: 125K;
Accessories: Cooling Fans, Enclosure ,Temperature Control;
Optional Protective Enclosure: IP00/IP20/IP23/Cutomized;
Applied Standards: GB/T10228, GB1094.11, IEC60076-11, DIN42523;
|