Specification |
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: up to 150mva;
Rated H. V.: 11~35kv or Customized;
Rated L. V.: 0.4kv or Customized;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 1000kVA;
Rated H. V.: 13.2kV;
Rated L. V.: 0.12kV;
Impedance: 4 %;
Cooling Way: AN/AF;
Winding: Cooper;
Core Material: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Accessories: Fans, Enclosure, etc;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: Intermediate Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 1500kVA;
Rated H. V.: 34.5kV;
Rated L. V.: 0.12kV;
Impedance: 4 %;
Cooling Way: AN/AF;
Winding: Cooper;
Core Material: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Accessories: Fans, Enclosure, etc;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Rectifier Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Capacity: 3150 kVA;
Rated H. V.: 11kV;
Rated L. V.: 0.4kV;
Impedance: 4~8%;
Insulation Level: IEC Standard;
Reference Standards: IEC60076;
Frequency: 50 Hz / 60 Hz;
Tapping Range: +2X2.5%/-2X2.5%;
Vector Group: Dyn11;
Winding Material: Copper;
Class of Protective Enclosure: 10;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
Package: Wooden Pallet, Wooden Case;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 2000kVA;
Rated H. V.: 11kV;
Rated L. V.: 0.69kV;
Impedance: 4-6%;
Cooling Way: AN/AF;
Winding: Cooper;
Core Material: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Accessories: Fans, Enclosure, etc;
|