Specification |
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Patient Monitor;
Group: Adult,Neo,PED;
Parameters: NIBP,SpO2,Temp,ECG,Resp;
Application: Adult, Neonate ,Child;
Optional Function: Etco2,IBP,HDMI,Touch Screen;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Biochemistry Analyzer;
Group: Female;
Product Name: Biochemistry Analyzer;
Throughput: 200tests/Hour;
Sample Positions: 49 Sample Positions;
Reagent Positions: 56 Reagent Positions;
Probewashing: Automaticwashing Interior and Exterior;
Cuvettes: 120 Reusable Cuvettes,Optical Length 6mm;
Stat Function: Yes;
Light Source: 12V/30W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Absorbance: 0~3.0ABS;
Software: Windows 7/8/10, Lis System Available;
Working Conditions: 30-80%;
Waterconsumption: Deionized Water:5L/H;
External Size (W*D*H): 950*612*510mm;
Package Size(W*D*H): 1118*728*1151mm;
|
Classification: Imaging Diagnostic Equipment;
Type: Urine Analyzer;
Group: Middle-aged and Old;
Throughput: 60 Samples/Hour;
Channels: 2;
Parameters: 21;
Histograms: 3 Histograms (Including Wbc, Rbc, Plt Histograms);
Sample Volume: Whole Blood: 10μl, Prediluted: 20μl;
Calibration: Manual, Auto Calibration;
Counting Modes: Venous, Capilary, Prediluted;
Printing Model: Auto Print, Manual Print;
Lis: Support Bi-Directional Lis;
Language: Chinese, English, Spanish, French, Russian, Ukrain;
Data Input: 9.7-Inch Touch Screen, Mouse, Keyboard (Optional);
Output: Internal Printer, Support External Printer;
Printer Paper: 57*30mm;
|
Classification: Biological Diagnostics;
Type: Thermal Cycler;
Group: All Ages;
Product Name: Gene Amplification Instrument Tec01;
Model: Tec01;
Capacity: 96;
Reaction Volume: 10~200μl;
Tube Type: 96×0.2mlpcr Plate, 8×0.2ml PCR Tube;
Block Temperature Range: 4-105 Degree;
Heat Lid Temperature Range: 30--101 Degree;
Display Resolution: ±0.1ºC;
Temperature Accuracy: ≤0.5ºC;
Temperature Uniformity: ≤1ºC;
Block Material: Aluminum;
Gradient Range: 30-90 Degree;
Temperature Differential Range: 1-42 Degree;
Program: a Single Program Can Be up to 30 Steps, 99 Cycles;
Display: 7”LCD;
|
Classification: Palm Type Aneroid Blood Pressure Monitor;
Type: Palm Type Aneroid Blood Pressure Monitor;
Group: Palm Type Aneroid Blood Pressure Monitor;
Bulb: Latex or PVC;
Cuff Size: 54*14.5cm;
Bladder Size: 22*12cm;
Gauge Material: ABS +Zinc Alloy;
Sub-Division: 2mmhg;
Packing: 1PC/Leather Bag;
Cuff Material: Nylon;
Accuracy: +/-3mmhg;
Measure Scope: 0-300mmhg;
Color: Optional;
Bladder: Latex or PVC;
|