Specification |
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 2500kVA;
High Voltage: 6kv;
Low Voltage: 0.4kv;
Impedance Voltage: 4%;
No-Load Loss: 3.6kw;
Load Loss: 18.8kw;
No-Load Current: 0.3%;
Frequency: 50/60Hz;
Connection Method: Yyn0/Dyn11;
Noise: 50dB;
Material: Aluminum/Copper;
Weight: 5900g;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Transformer Type: Cast Resin Dry Type Transformer;
Rated Capacity: 3150 kVA;
Rated Voltage(Hv/LV): 33/0.69 kV;
Frequency: 50 Hz;
Impedance: 4~6%;
Tapping Range: +2X2.5%/-2X2.5%;
Vector Group: Dyn11;
Winding Material: Copper;
Core Materials: Silicon Steel;
Insulation Level: as Per IEC Standard;
Temperature Rise: 125K;
Accessories: Fans, Enclosure;
Optional Protective Enclosure: IP00/IP20/IP23/Cutomized;
Applied Standards: GB/T10228, GB1094.11, IEC60076-11, DIN42523;
Cooling Way: AN/AF;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Transformer Type: Cast Resin Dry Type Transformer;
Rated Capacity: 3150 kVA;
Rated Voltage(Hv/LV): 33/0.69 kV;
Frequency: 50 Hz;
Impedance: 4~6%;
Tapping Range: +2X2.5%/-2X2.5%;
Vector Group: Dyn11;
Winding Material: Copper;
Core Materials: Silicon Steel;
Insulation Level: as Per IEC Standard;
Temperature Rise: 125K;
Accessories: Fans, Enclosure;
Optional Protective Enclosure: IP00/IP20/IP23/Cutomized;
Applied Standards: GB/T10228, GB1094.11, IEC60076-11, DIN42523;
Cooling Way: AN/AF;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Rated Capacity: 50-31500 kVA;
High Voltage: 11kv;
Low Voltage: 0.4kv/0.415kv;
Ambient Temperature: 40ºC -+ 40ºC;
No-Load Loss: 0.17-3.24kw;
Load Loss: 0.71-17.7kw;
Frequency: 50Hz/60Hz;
Connection Group: Dyn11 Yyn0;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
High Voltage: 11kv;
Low Voltagewinding: 0.4kv 0.415kv;
Frequency: 50Hz/60Hz;
Rated Capacity: 50-31500 kVA;
Connection Group: Dyn11;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
Ambient Temperature: -40ºC -+ 40ºC;
|