Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Usage Category: Category a;
Mechanical Life(Time): 4000;
Electrical Life(Time): 1000;
Rated Current of Frame Size Inm(a): 400A;
Arcing Distance (mm): <100;
Rated Impulse Withstand Voltage Uimp (V): 12kv;
Rated Insulation Voltage Ui (V): 1000V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1/2/3/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: DC MCB 1000V 10A 16A 20A 63A;
Votage: 440V 550V 800V 1000V 1200V;
Ampes: 6,10,16,20,25,32,40,50,60A;
Pole: 1p,2p,3p,4p;
Curve Type: C;
Trip Type: Thermal-Magnetic;
Installation Category: Class III;
Pollution Level: 3;
Installation Environment: No Obvious Shock and Vibration;
Ambient Tempersture: -20--70;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1/2/3/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: 4p DC MCB 1200V 6A-63A Solar;
Votage: 440V 550V 800V 1000V 1200V;
Ampes: 6,10,16,20,25,32,40,50,60A;
Pole: 1p,2p,3p,4p;
Curve Type: C;
Trip Type: Thermal-Magnetic;
Installation Category: Class III;
Pollution Level: 3;
Installation Environment: No Obvious Shock and Vibration;
Ambient Tempersture: -20--70;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1/2/3/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: Best Quality IEC60947 Mrl7-63 1p 2p 3p 4p 10A 16A;
Votage: 440V 550V 800V 1000V 1200V;
Ampes: 6,10,16,20,25,32,40,50,60A;
Pole: 1p,2p,3p,4p;
Curve Type: C;
Trip Type: Thermal-Magnetic;
Installation Category: Class III;
Pollution Level: 3;
Installation Environment: No Obvious Shock and Vibration;
Ambient Tempersture: -20--70;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
|