Specification |
Type: Combustible Gas Detector;
Types of Smoke Detectors: Gas Detectors;
Infrared Sensor Installation: Ceiling;
Power Source: DC 3V Battery;
Operation Current: <=5ua;
Comply with Standard: En 50291;
Alarm Volume: >85dB(a) @ 1 Meters;
Low Voltage Threshold: <=2.4V;
Hush Time: 2minutes;
Product Service Life: 7 Years;
Humidity Range: < 95% Relative Humidity (Rh);
Temperature Range: -10c to 50c;
Size: 90mm in Diameter X 35.5mm Depth;
|
Type: Infrared Sensor Probe;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Infrared Beam Smoke Style;
Infrared Sensor Installation: Wall Mounted;
Product Name: Fire Alarm Beam Smoke Detector;
Operating Voltage: 20V to 28VDC;
Standby Current: 23mA;
Alarm Current: 33mA;
Commission Current: 56mA;
Beam Pathway Length: 8-100 Meters;
Beam Path Angle: ±0.4º Directional;
LED Indicator Guide: Red: Fire ; Yellow: Fault ; Green: Alignment;
Dimention: About L:191 X W:127 X H:92 mm;
Material: ABS Plastic;
Standard: EN54-12:2002;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detection, Fire Alarm System;
Application: Warehouse,Shopping Mall,Exhibition Hall,Hotel etc.;
|
Type: Infrared Sensor Probe;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Infrared Beam Smoke Style;
Infrared Sensor Installation: Wall Mounted;
Product Name: Fire Alarm Beam Smoke Detector;
Operating Voltage: 20V to 28VDC;
Standby Current: 23mA;
Alarm Current: 33mA;
Commission Current: 56mA;
Beam Pathway Length: 8-100 Meters;
Beam Path Angle: ±0.4º Directional;
LED Indicator Guide: Red: Fire ; Yellow: Fault ; Green: Alignment;
Dimention: About L:191 X W:127 X H:92 mm;
Material: ABS Plastic;
Standard: EN54-12:2002;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detection, Fire Alarm System;
Application: Warehouse,Shopping Mall,Exhibition Hall,Hotel etc.;
|
Type: Infrared Beam Smoke Detector;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Infrared Beam Smoke Style;
Infrared Sensor Installation: Wall Mounted;
Product Name: Flame Proof Beam Smoke Detector Industrial;
Operating Voltage: 24VDC;
Standby Current: ≤10mA;
Alarm Current: ≤25mA;
Indicator: Red, Green, Yellow LED;
Detection Distance: 3-100m;
Detector Protective Diameter: 14m;
Protected Area: Ideal Maximum Is 100X14m;
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 197X195X116mm;
Operating Temperature: -15ºC- +50ºC;
Operating Humidity: ≤95% Rh;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|
Type: Infrared Beam Smoke Detector;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Infrared Beam Smoke Style;
Infrared Sensor Installation: Wall Mounted;
Product Name: Flame Proof Beam Smoke Detector Industrial;
Operating Voltage: 24VDC;
Standby Current: ≤10mA;
Alarm Current: ≤25mA;
Indicator: Red, Green, Yellow LED;
Detection Distance: 3-100m;
Detector Protective Diameter: 14m;
Protected Area: Ideal Maximum Is 100X14m;
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 197X195X116mm;
Operating Temperature: -15ºC- +50ºC;
Operating Humidity: ≤95% Rh;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|