Specification |
After-sales Service: One Year;
Warranty: One Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater;
Size: DN25-DN900;
Sensor: Clamp-on/External;
Application: Industrial Production;
Type: Vortex Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Installation Mounting Styles: Panel Mount/Field Mount;
Types of Installation Fittings: Weld-on/Clamp/Saddle/Tee;
Sensor Style: Insertion Paddlewheel/Magmeter;
Sensor Material: Metal;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Size: DN100-500;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Protection Class: IP65;
Environment Temperature: -20c~60c;
Output Signal: 4-20madc;
Alarm Output: Rated Value 30V DC, 100mA;
Communication Signal: RS485 Communication Protocol;
Load Resistance: 250omega~ 600omega;;
Diameter of Flowmeter: mm;
Rated Voltage of Power Supply: 220V AC: 100V~240V AC;
Wire Terminals: M3 Screw;
Housing Material: Aluminum Alloy;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Chemical;
Size: Dn80;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Coriolis Mass Flow Meter;
Measuring Media: Gases/Liquids/Slurries;
Measuring Principle: Coriolis Force;
Measurement Object: All;
Max. Flow Rate: 0~200kg/Min;
Nominal Diameter: 25mm( 1 Inch);
Mwp.: 4MPa;
Voltage: AC85~265V, DC12~28V;
Warranty: 2 Years;
Wetted Parts: Stainless Steel 316L;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Size: DN100-500;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Protection Class: IP65;
Environment Temperature: -20c~60c;
Output Signal: 4-20madc;
Alarm Output: Rated Value 30V DC, 100mA;
Communication Signal: RS485 Communication Protocol;
Load Resistance: 250omega~ 600omega;;
Diameter of Flowmeter: mm;
Rated Voltage of Power Supply: 220V AC: 100V~240V AC;
Wire Terminals: M3 Screw;
Housing Material: Aluminum Alloy;
|
Accuracy: ≤±0.1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN50-100;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid & Gas;
Measuring Principle: Coriolis Force;
Measurement Object: Closed Pipeline;
|