Specification |
Application: Power, Electronic, Instrument, Rectifier, Power Grid, Power Station, Substation;
Phase: Three;
Core: Hollow Core Reactor;
Cooling Method: Natural Cooling;
Winding Type: Hollow Core Reactor;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Power System Filtering Current Limiting;
Frequency Characteristics: Power Frequency;
Shape of Core: Hollow Core Reactor;
Brand: Shanghai Zhiyou;
Main Sales Regions (Seeking Cooperative: North America, South America, Europe, Central Asia;
Application Scenario: Power Grid, Power Station, Substation;
Product Certification: CE,ISO9001,ISO14001;
Product Model: Xkgkl,Bkgkl,Lkgkl,Ckdkl,Pkgkl,Qkgkl;
Reactance Rate: 4%,5%,6%,8%,10%,12%,14%,16%,18%,20%,24%;
Insulation Level: H-Level or F-Level;
External Dimensions: 2000mm×1600mm×1800mm;
Product Structure: Hollow Core Reactor, Hollow Core Re;
System Rated Voltage: 6kv,10kv,35kv,66kv,110kv;
Rated Frequency: 50Hz;
Rated Current: 1000A,1200A,1500A,1800A,2000A,2500A,3000A,4000A;
Rated Mechanical Short-Circuit Current: ≥ 2.55 Times The Rated Short-Term Current;
DC Resistance Three-Phase Unevenness: ≤1%;
Interturn Insulation Heat Resistance: H Leve;
Reactor Form: Hollow Reactor;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 800~25000kVA;
Rated H. V.: 35kv;
Rated L. V.: 0.4kv;
Impedance: 4 %;
Cooling Way: an/Af;
Winding: Cooper/Aluminum;
Core Material: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Enclosure: IP20/IP23;
Accessories: Fans, Enclosure;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 800~25000kVA;
Rated H. V.: 35kv;
Rated L. V.: 0.4kv;
Impedance: 4 %;
Cooling Way: an/Af;
Winding: Cooper/Aluminum;
Core Material: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Enclosure: IP20/IP23;
Accessories: Fans, Enclosure;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Oil Immersed Tranformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Power Transformer;
Reference Standards: IEC 60076;
Capacity: 6300~180000kVA;
Rated H. V.: 110kv;
Rated L. V.: 6.3-11kv;
Cooling Way: Onan/Onaf;
Impedance: as Per IEC Standard;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
AC Withstand Voltage: as Per IEC Standard;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Oil Immersed Tranformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Power Transformer;
Reference Standards: IEC 60076;
Capacity: 6300~180000kVA;
Rated H. V.: 110kv;
Rated L. V.: 6.3-11kv;
Cooling Way: Onan/Onaf;
Impedance: as Per IEC Standard;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
AC Withstand Voltage: as Per IEC Standard;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
|