Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ACB;
Poles Number: 1p, 2p, 3p, 4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Shell Frame Rated Current Inm (a): 2000,3200,4000,6300;
ICU(Ka)O-Co: 80,100,120;
Rated Short-Circuit Capacity: 105/0.25,143/0.2,165/0.2;
Rated Running Short Circuit Breaking Cap: 50,60,80,100;
Standard: IEC60947-2;
Rated Insulation Voltage Ui (V): 800;
Rated Impluse Withstand Voltage Uimp (Kv: 8;
Mechanical Endurance: 8500;
Electrical Endurance: 1500;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p, 2p, 3p, 4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Shell Frame Rated Current Inm (a): 2000,3200,4000,6300;
ICU(Ka)O-Co: 80,100,120;
Rated Short-Circuit Capacity: 105/0.25,143/0.2,165/0.2;
Rated Running Short Circuit Breaking Cap: 50,60,80,100;
Standard: IEC60947-2;
Rated Insulation Voltage Ui: 800;
Rated Impluse Withstand Voltage Uimp (Kv: 8;
Mechanical Endurance: 4000;
Electrical Endurance: 1000;
Fixed Magnetic Trip: Has This Option;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 1p, 2p, 3p, 4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Shell Current(a): 100,225,400,638(800);
Rated Current(a): 10,16,20,32,40,50,63,80,;
Rated Insulated Voltage(V): 690;
Rated Voltage(V): 400;
Rated Impluse Withstand Voltage Uimp(Kv): 8;
Mechanical Endurance: 8500;
Electrical Endurance: 1500;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 1p, 2p, 3p, 4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Shell Current(a): 100,225,400,638(800);
Rated Current(a): 32,100,225,400,630;
Rated Insulated Voltage(V): 690;
Rated Voltage(V): 400;
Standard: IEC60947;
Rated Impulse Withstand Voltage Uimp Kv: 8;
|