Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Intdoor Vacuum Circuit Breaker;
Orign of Place: Zhejiang ,China;
Related Voltage: up to 12kv;
Rated Frequency: 50/60Hz;
Rated Current: up to 2500A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 20000 Times;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Intdoor Vacuum Circuit Breaker;
Orign of Place: Zhejiang ,China;
Related Voltage: up to 12kv;
Rated Frequency: 50/60Hz;
Rated Current: up to 1250A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 10000 Times;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection, OVP(Overvoltage Protection);
Delivery Time: Within 15days;
Rated Voltage: AC 400,380V, 220V, 127V; DC 48V, 36V, 24V;
Moving Voltage: (70%-110%) X Ue;
Standards: IEC60947-3, GB14048.3;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Intdoor Vacuum Circuit Breaker;
Orign of Place: Zhejiang ,China;
Related Voltage: up to 12kv;
Rated Frequency: 50/60Hz;
Rated Current: up to 1250A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 10000 Times;
|