Specification |
Application: Power, Electronic, Instrument, Lighting, Rectifier, Electrical Power;
Phase: Three;
Core: Shell-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Brand: Chsh;
Place of Origin: Zhejiang, China;
Standard: IEC60076;
Rated Capacity: 30kVA~2500kVA;
Input Voltage: 6.3kv;
Core Material: Copper\Aluminum;
Model Number: S11-M;
Brand Name: Chsh;
Vector Group: Dyn11 / Yyn0/Yzn11;
Coil Number: Two Winding;
Coil Structure: Toroidal;
Frequency: 50Hz;
Output Voltage: 440V;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
High Voltage: 33kv;
Low Voltage: 0.4kv;
Frequency: 50Hz/60Hz;
Connection Group: Dyn11 Yyn0;
No-Load Loss: 0.83-2.0kw;
No-Load Current: 1.1-0.32%;
Short-Circuit Impedance: 6.5-8.0;
Rated Capacity: 630-31500kVA;
Ambient Temperature: -40ºC -+ 40ºC;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou;
Rated Capacity: 50-31500 kVA;
H.V. Winding: 11kv/12kv/20kv/33kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Rated Capacity: 100-3500kVA;
High Voltage: 11kv 6kv 6.6kv 15kv 20kv;
Low Voltage: 0.4kv/0.415kv;
Ambient Temperature: 40ºC -+ 40ºC;
No-Load Loss: 0.17-3.24kw;
Load Loss: 0.71-17.7kw;
Frequency: 50Hz/60Hz;
Connection Group: Dyn11 Yyn0;
|