Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 2;
Type: Circuit Breaker;
Function: Overcurrent Protection, RCCB, short circuit;
Standard: IEC 61009-1;
Pole: 1P+N;
Tripping curve: B, C, D;
Rated Current (in): 63A;
Mode: Electromagnetic;
Residual Current Type: Ac;
Residual Current (LΔn): 30mA;
Icn: 10kA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 4, 000;
Keyword 1: circuit breaker;
Keyword 2: RCBO Breaker;
Keyword 3: RCBO;
Keyword 4: residuel current circuit breaker with overcurrent;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p+N, 3p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Production Line: 100% Automic;
Ka: 4.5ka, 6ka;
Cooperation Type: OEM ODM;
Voltage: AC230V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p+N, 3p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Production Line: 100% Automic;
Ka: 4.5ka, 6ka;
Cooperation Type: OEM ODM;
Voltage: AC230V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Open Frame;
Structure: MCCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: 230/400V AC;
Application: Solar PV System/EV Charger System;
Inc: 6/10ka;
Mode: Electromagnetic / Electronic;
Rated Current (in): 25/40/63/80/100A;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail 35;
Structure: MCB;
Poles Number: 1P, 2P, 3P, 4P;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Standard: EN60947-2, AS/NZS IEC 60947.2;
Altitude: 2000M, if higher, then derate;
Operation ambient temperature: -30 centigrade to 70 centigrade;
Storage temperature: -40 centigrade to 85 centigrade;
|