Model | Diesel Generator | Diesel Engine | Alternator | Size (mm) | Weight(KG) |
| Prime Power (KW/KVA) | Max Power (KW/KVA) | Model | Power (KW) | Model | Power (KW/KVA) | | |
VLC16GF | 16/20 | 18/22 | 4B3.9-G1 | 24 | TFW16 | 16/20 | 1800×760×1430 | 780 |
VLC20GF | 20/25 | 22/28 | 4B3.9-G1 | 24 | TFW20 | 20/25 | 1800×760×1430 | 800 |
VLC22GF | 22/28 | 24/30 | 4B3.9-G1 | 24 | TFW22 | 22/28 | 1800×760×1430 | 830 |
VLC24GF | 24/30 | 26/33 | 4BT3.9-G1 | 36 | TFW24 | 24/30 | 1800×760×1430 | 846 |
VLC28GF | 28/35 | 31/39 | 4BT3.9-G1 | 36 | TFW28 | 28/35 | 1800×760×1430 | 880 |
VLC32GF | 32/40 | 35/44 | 4BT3.9-G1 | 36 | TFW32 | 32/40 | 1800×760×1430 | 896 |
VLC34GF | 34/43 | 37/47 | 4BT3.9-G1 | 36 | TFW34 | 34/43 | 1800×760×1430 | 906 |
VLC40GF | 40/50 | 44/55 | 4BTA3.9-G2 | 50 | TFW40 | 40/50 | 1900×760×1430 | 1030 |
VLC48GF | 48/60 | 53/66 | 4BTA3.9-G2 | 50 | TFW48 | 48/60 | 1900×760×1430 | 1050 |
VLC58GF | 58/73 | 64/80 | 6BT5.9-G1 | 92 | TFW58 | 58/73 | 2150×830×1496 | 1215 |
VLC68GF | 68/85 | 74/94 | 6BT5.9-G1 | 92 | TFW68 | 68/85 | 2150×830×1496 | 1255 |
VLC80GF | 80/100 | 88/110 | 6BT5.9-G1 | 92 | TFW80 | 80/100 | 2150×830×1496 | 1300 |
VLC96GF | 96/120 | 106/132 | 6BTA5.9-G2 | 110 | TFW96 | 96/120 | 2150×830×1496 | 1335 |
VLC112GF | 112/140 | 123/154 | 6BTAA5.9-G2 | 120 | TFW112 | 112/140 | 2150×830×1496 | 1425 |
VLC128GF | 128/160 | 141/176 | 6 TA8.3-G2 | 163 | TFW128 | 128/160 | 2450×850×1516 | 1695 |
VLC144GF | 144/180 | 158/198 | 6 TA8.3-G2 | 163 | TFW144 | 144/180 | 2450×850×1516 | 1815 |
VLC160GF | 160/200 | 176/220 | 6 TAA8.3-G2 | 183 | TFW160 | 160/200 | 2540×945×1550 | 1874 |
VLC184GF | 184/230 | 202/253 | 6LTAA8.9-G2 | 220 | TFW184 | 184/230 | 2540×945×1550 | 2020 |
VLC200GF | 200/250 | 220/275 | 6LTAA8.9-G2 | 220 | TFW200 | 200/250 | 2540×945×1550 | 2080 |
VLC240GF | 240/300 | 264/330 | NTA855-G1A | 261 | TFW240 | 240/300 | 3150×1120×1630 | 2970 |
VLC260GF | 260/325 | 286/358 | NTA855-G1B | 283 | TFW260 | 260/325 | 3100×1100×1635 | 3198 |
VLC280GF | 280/350 | 308/385 | NTA855-G2A | 313 | TFW280 | 280/350 | 3100×1100×1635 | 3198 |
VLC304GF | 304/380 | 334/418 | NTAA855-G7 | 343 | TFW304 | 304/380 | 3250×1190×1700 | 3200 |
VLC320GF | 320/400 | 352/440 | NTAA855-G7A | 370 | TFW320 | 320/400 | 3300×1150×1700 | 3260 |
VLC400GF | 400/500 | 440/550 | KTA19-G4 | 457 | TFW400 | 400/500 | 3500×1375×1980 | 3950 |
VLC450GF | 450/563 | 495/619 | KTAA19-G5 | 470 | TFW450 | 450/563 | 3700×1750×2030 | 4200 |
VLC500GF | 500/625 | 550/688 | KTAA19-G6A | 554 | TFW500 | 500/625 | 3700×1750×2030 | 4200 |
VLC600GF | 600/750 | 660/825 | KTA38-G2 | 664 | TFW600 | 600/750 | 4490×1630×2430 | 7800 |
VLC640GF | 640/800 | 704/880 | KTA38-G2 | 664 | TFW640 | 640/800 | 4490×1630×2430 | 8500 |
VLC720GF | 720/900 | 792/990 | KTA38-G2A | 813 | TFW720 | 752/940 | 4490×1630×2430 | 8560 |
VLC800GF | 800/1000 | 880/1100 | KTA38-G5 | 880 | TFW800 | 824/1030 | 4510×1850×2500 | 9120 |
VLC900GF | 900/1125 | 990/1238 | KTA38-G9 | 990 | TFW900 | 900/1125 | 4850×1850×2500 | 9400 |
VLC1000GF | 1000/1250 | 1100/1375 | KTA50-G3 | 1115 | TFW1000 | 1008/1260 | 4950×2080×2560 | 10120 |
VLC1200GF | 1200/1500 | 1320/1650 | KTA50-G8 | 1299 | TFW1200 | 1240/1550 | 5400×2195×2560 | 10600 |
.Contorl panel including Voltage,Current,Frequency, Teperature,Pressure meters, can control and check the genset any time. 3.Soundproof canopy and under frame use strong steel meterial,Stoving varnish printed, beathigh temperature and Corrsion demage. 4.The connection of raditor,generator with under frame, use highly rubber dampingblock,reduce the vibration during genset moving or running time,make good protect. 5.Raditor, including Double vents, exhaust heat to achieve high efficiency 6.Battery breaker included, protect the battery if do not star the generator, easy siwthch,increase the batery life for years etc. 7.Non-maintenance battery ,we adopt the famous brand Camel batteries. 8.Test. All generators before delivery need pass two time test,each time will make the testunder loading .check the voltage, current, frequency,temperatue,exhaust normal or not .Testreport will including the package with the genset 9.Experience, all our engineers have years experience in engines and power plant, make itour generators stable and easy operational. 10.Service. Our company do service for the genset during its life time,each two or threemonthes will make the contact for user, check the generator conditions, offer support oftechnology or desgin or other support for your project etc. 11.Spare parts, for complete sets, all spare parts avaible all the time, whatever whichtime you need them, we can directly send it without delay,and make you can find us alltime. 12.Delivery mostly we have more than 100 hundreds sets in stock for sale, make it fastdelivery after the payment,no need wait long time. 13.Warranty: All complete generators we offer 1 year warranty, alternators, make 2 yearswarranty Company Main business:Professional supplier for diesel generators, gasoline generators,diesel engines,and spareparts.Generators power range from 1kw to 2000kw,spare parts for variety engines etc.We all have in stock, delivery fast,global service,make us as leader in this line.
Address:
Hefang Town, Binzhou, Shandong, China
Business Type:
Manufacturer/Factory
Business Range:
Agriculture & Food, Apparel & Accessories, Construction & Decoration, Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy, Tools & Hardware
Management System Certification:
ISO 9001
Company Introduction:
Vol machinery company professional in Generators line for years. Generator production capacity from 1kw to 2000kw with Variety engines like Weichai/Deutz/Ricardo/Yuchai/Shangchai etc. Alternators adopt Stamford/Marathon/Faraday/Leroy-Somer etc.
Generators widely used as prime work or back up power supply